Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 253
Filter
1.
International Eye Science ; (12): 82-87, 2024.
Article in Chinese | WPRIM | ID: wpr-1003511

ABSTRACT

Keratoconus is a progressive blinding eye disease that characterized by corneal thinning and protrusion, which accompanied with irregular astigmatism and impaired visual acuity.The irregular astigmatism of early keratoconus can be corrected by spectacles. For the irregular astigmatism of moderate to severe keratoconus, spectacles are no longer suitable, and contact lenses are the best choice for patients to restore vision. There are various types of contact lenses, making the selection very difficult. In addition, trying on lenses for a long time will increase the discomfort and overall feeling of patients, and greatly increase the workload of doctors. Thus, the article aims to summarize and discuss the classification of contact lenses, the application of contact lenses in different types of keratoconus, the complications of contact lens, and the current status and prospect of contact lenses, with a view to understanding the management and clinical application of contact lenses in keratoconus patients and to further improving the application value of contact lenses in keratoconus.

2.
Arq. bras. oftalmol ; 86(4): 330-336, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447371

ABSTRACT

ABSTRACT Purpose: To evaluate the efficacy of soft HydroCone silicone hydrogel contact lenses in patients with posterior microphthalmos. Methods: The charts of 13 patients with posterior microphthalmos (26 eyes) who were fitted with soft HydroCone silicone hydrogel contact lenses were reviewed retrospectively. All the patients underwent assessments of uncorrected and best spectacle-corrected visual acuity and cycloplegic refraction. They were fitted with contact lenses according to the parameter values obtained from the topographical analysis and best contact lens-corrected visual acuity measurement. Results: The spherical equivalents of the right and left eyes ranged from 10.00 to 19.25 diopters and from 11.00 to 21.5 diopters, respectively. The mean axial and posterior chamber lengths were shorter than those of the age-matched population. However, the mean values of the anterior segment parameters such as horizontal visible iris diameter, central anterior chamber depth, lens thickness, and central corneal thickness were in the normal range. The mean keratometric measurements revealed increased corneal curvature compared with that in the normal population. The mean best contact lens-corrected visual acuity was significantly higher than the mean best spectacle-corrected visual acuity for both eyes (p=0.045). Conclusion: HydroCone silicon soft contact lenses provided better visual acuity than spectacles in the patients with posterior microphthalmos in this study.


RESUMO Objetivo: Avaliar a eficácia das lentes de contato gelatinosas HydroCone, de hidrogel com silicone, em pacientes com microftalmia posterior. Métodos: Foram revisados retrospectivamente 26 olhos com microftalmia posterior, a partir dos prontuários de 13 pacientes que receberam lentes de contato gelatinosas HydroCone, de hidrogel com silicone. Todos os pacientes foram submetidos ao exame de acuidade visual não corrigida e com melhor correção por óculos e com refração cicloplégica. Todos os pacientes receberam lentes de contato de acordo com os parâmetros obtidos na análise topográfica e foi obtida a melhor acuidade visual corrigida com lentes de contato. Resultados: O equivalente esférico do olho direito variou de 10,00 a 19,25 dioptrias, e o do olho esquerdo de 11,00 a 21,5 dioptrias. Os comprimentos médios axiais e das câmaras posteriores foram menores do que para a população de mesma idade. No entanto, os valores médios dos parâmetros do segmento anterior, como o diâmetro horizontal visível da íris, a profundidade da câmara anterior central, a espessura da lente e a espessura central da córnea estavam dentro da faixa normal. Os valores médios da ceratometria revelaram curvatura corneana aumentada em relação à população normal. A média da melhor acuidade visual corrigida com lentes de contato foi significativamente maior que a média da melhor acuidade visual corrigida com óculos em ambos os olhos (p=0,045). Conclusão: As lentes de contato gelatinosas de silicone HydroCone proporcionam melhor acuidade visual que óculos em pacientes com microftalmia posterior.

3.
Indian J Ophthalmol ; 2023 May; 71(5): 1855-1861
Article | IMSEAR | ID: sea-225069

ABSTRACT

Purpose: To compare post?operative pain perception using bandage contact lens (BCL) stored at 2–8?C (Cold BCL, CL?BCL) or room temperature (23 – 25?C, RT?BCL) after photorefractive keratectomy (PRK) or corneal collagen?crosslinking (CXL) and determine status of nociception associated factors. Methods: In this prospective interventional study, 56 patients undergoing PRK for refractive correction and 100 keratoconus (KC) undergoing CXL were recruited following approval from the institutional ethics committee with informed consent. Patients undergoing bilateral PRK received RT?BCL on one eye and CL?BCL on the other. Pain was graded by Wong–Baker scoring on the first post?operative day (PoD1). Expression of transient receptor potential channels (TRPV1, TRPA1, TRPM8), calcitonin gene?related peptide (CGRP) and IL?6 was measured in cellular content from used BCLs collected on PoD1. Equal number of KC patients received RT?BCL or CL?BCL post?CXL. Pain was graded by Wong–Baker scoring on PoD1. Results: Pain scores on PoD1 were significantly (P < 0.0001) reduced in subjects receiving CL?BCL (Mean ± SD: 2.6 ± 2.1) compared to RT?BCL (6.0 ± 2.4) post?PRK. 80.4% of subjects reported reduced pain scores with CL?BCL. 19.6% reported no change or increased pain scores with CL?BCL. TRPM8 expression was significantly (P < 0.05) increased in BCL of subjects reporting reduced pain with CL?BCL compared to those who did not. Pain scores on PoD1 were significantly (P < 0.0001) reduced in subjects receiving CL?BCL (3.2 ± 2.1) compared to RT?BCL (7.2 ± 1.8) post?CXL. Conclusion: The simple approach of using a cold BCL post?operatively substantially reduced pain perception and could overcome post?operative pain?related limited acceptance of PRK/CXL.

4.
Indian J Ophthalmol ; 2023 May; 71(5): 1837-1842
Article | IMSEAR | ID: sea-225036

ABSTRACT

Purpose: To compare the visual performance of two simultaneous?vision soft multifocal contact lenses and to compare multifocal contact lens and its modified monovision counterpart in presbyopic neophytes. Methods: A double?masked, prospective, comparative study was conducted on 19 participants fitted with soft PureVision2 multifocal (PVMF) and clariti multifocal (CMF) lenses in random order. High? and low?contrast distance visual acuity, near visual acuity, stereopsis, contrast sensitivity, and glare acuity were measured. The measurements were conducted using multifocal and modified monovision design with one brand and then repeated with another brand of lens. Results: High?contrast distance visual acuity showed a significant difference between CMF (0.00 [?0.10–0.04]) and PureVision2 modified monovision (PVMMV; ?0.10 [?0.14–0.00]) correction (P = 0.003) and also between CMF and clariti modified monovision (CMMV; ?0.10 [?0.20–0.00]) correction (P = 0.002). Both modified monovision lenses outperformed CMF. The current study did not show any statistically significant difference between contact lens corrections for low?contrast visual acuity, near visual acuity, and contrast sensitivity (P > 0.01). Stereopsis at near distance was significantly lower with both modified monovision (PVMMV: 70 [50–85]; P = 0.007, CMMV: 70 [70–100]; P = 0.006) and with CMF (50 [40–70]; P = 0.005) when compared to spectacles (50 [30–70]). Glare acuity was significantly lower with multifocal (PVMF: 0.46 [0.40–0.50]; P = 0.001, CMF: 0.40 [0.40–0.46]; P = 0.007) compared with spectacles (0.40 [0.30–0.40]), but no significant difference was noted between the multifocal contact lenses (P = 0.033). Conclusion: Modified monovision provided superior high?contrast vision compared to multifocal correction. Multifocal corrections performed better for stereopsis when compared to modified monovision. In parameters like low?contrast visual acuity, near acuity, and contrast sensitivity, both the corrections performed similarly. Both multifocal designs showed comparable visual performances.

5.
Article | IMSEAR | ID: sea-218454

ABSTRACT

Mini-scleral lens’ are large diameter rigid lenses that are used to rehabilitate vision when the corneal shape is distorted from disease, scarring or after a corneal graft procedure, however, there are relatively few reports regarding their potential complications, in this case we describe the case of a corneal abscess in a mini-scleral lens wearer with keratoconus in order to determine whether this type of contact lens presents an increased risk of infection.

6.
International Eye Science ; (12): 2096-2099, 2023.
Article in Chinese | WPRIM | ID: wpr-998497

ABSTRACT

AIM:To assess the clinical efficacy of 5-fluorouracil(5-FU)and bandage contact lens in the pterygium excision combined with autogenous limbal stem cell transplantation(ALSCT)in treating patients with pterygium.METHODS:Random controlled clinical trial. A total of 71 patients(71 eyes)of pterygium who treated at the department of ophthalmology in Qinhuangdao Haigang Hospital between May 2021 and November 2022 were included. They were divide into three groups, including 23 eyes received pterygium excision combined with ALSCT in group A, 24 eyes that were administered with 5-FU intraoperatively and postoperatively in group B, and 24 eyes that received both bandage contact lens and 5-FU in group C. Furthermore, comfort levels at 1, 3, 7, 14d postoperatively, corneal epithelial healing at 1, 3, 7, 14d and 1mo postoperatively, treatment outcomes and complications at 3~6mo postoperatively were compared among the three groups of patients.RESULTS:The comfort levels at 1, 3 and 7d postoperatively and corneal healing at 1 and 3d postoperatively of the group C were better than those of the groups A and B. There were no statistical significant differences in the comfort levels at 14d after surgery and corneal healing at 14d and 1mo after surgery among the three groups of patients. Over a 3~6mo follow-up period, group A experienced recurrence in 3 eyes, group B had 1 recurrence, while group C had no recurrence. There were no statistically significant differences in complication rates among the three groups of patients.CONCLUSIONS: The application of 5-FU combined with bandage contact lens can enhance postoperative comfort levels, promote corneal epithelial healing, and improve the success rate in pterygium excision combined with ALSCT.

7.
International Eye Science ; (12): 923-927, 2023.
Article in Chinese | WPRIM | ID: wpr-973778

ABSTRACT

Contact lens(CL)is currently one of the most common methods of vision correction, with more than 140 million users worldwide and the demand is rising yearly as constantly development of materials and features. Wearing CL can lead to a variety of complications such as dry eye, corneal abrasions, giant papillary conjunctivitis, and infectious keratitis is one of the most severe complications. According to research, bacteria account for 80%~95% of the pathogens that cause CL-associated infective keratitis, it may have been related to the bacterial composition, virulence mechanism, biofilm formation and the combined effect of the lens itself and the process of use, which is prone to introducing pathogens, reducing antimicrobial capacity of the cornea and tears and causing ocular surface hypoxia and ocular surface inflammation. Overnight and prolonged lens wear, irregular lens purchase, use and care procedures can also be risk factors for bacterial infections. This article reviews the studies on the pathogenesis, risk factors, diagnosis, treatment and prevention of CL-related bacterial keratitis.

8.
International Eye Science ; (12): 466-470, 2023.
Article in Chinese | WPRIM | ID: wpr-964250

ABSTRACT

AIM: To determine the correlation among horizontal ciliary sulcus(HCS)diameter, vertical ciliary sulcus(VCS)diameter and corneal diameter in different anterior chamber depth(ACD)levels from patients with low to moderate myopia.METHODS: Retrospective study. A total of 78 patients(129 eyes)with low to moderate myopia who had preoperative examination of implantable contact lens(ICL)implantation in Shanghai Bright Eye Hospital from April 2021 to April 2022 were included. HCS, VCS and white to white(WTW)were measured and compared. Patients were divided into shallow ACD group(2.8 mm ≤ ACD ≤3.2 mm), medium ACD group(3.2 mm < ACD ≤3.4 mm)and deep ACD group(ACD > 3.4 mm)based on the ACD obtained by Pentacam. The HCS, VCS and WTW within and among groups were compared, and the correlation of WTW, HCS and VCS among each group was analyzed by Pearson and linear regression equation.RESULTS: There was no statistical difference in WTW and HCS overall and in groups with different ACD(P>0.05), while there was difference between VCS and both HCS and WTW(P<0.01). The WTW had a correlation with both HCS and VCS in each group, while correlation between WTW and VCS was weak in the deep ACD group(r=0.470, R2=0.221, P<0.01). Furthermore, the WTW, HCS and VCS in the shallow ACD group were statistically different from those in the medium and deep ACD groups(P<0.01).CONCLUSION: The WTW was suggested predicting HCS rather than perfectly replacing HCS before patients had the ICL operation among patients with low to moderate myopia. The predictability of VCS would decline as the ACD depth increasing, predicting VCS by WTW was not recommended.

9.
International Eye Science ; (12): 345-348, 2023.
Article in Chinese | WPRIM | ID: wpr-960964

ABSTRACT

AIM: To observe the efficacy of moderate and high myopia patients with vault greater than 1 000μm after implantation of phakic posterior chamber implantable contact lens(ICL).METHODS: A total of 42 patients(73 eyes)who received ICL implantation in the hospital and had postoperative vault greater than 1 000 μm between January 2014 and January 2017 were selected and retrospectively studied. Changes in visual acuity, intraocular pressure, corneal endothelial cell density, anterior chamber-related parameters(chamber angle, central anterior chamber depth, anterior chamber volume)and vault were compared among patients before surgery, at 1, 3, 6mo and 1a after surgery and at the last follow-up.RESULTS: The uncorrected visual acuity(UCVA)at 1, 3, 6mo and 1a after surgery and at the last follow-up was better than that before surgery(all P&#x0026;#x003C;0.05), and the chamber angle, central anterior chamber depth and anterior chamber volume were smaller or lower than those before surgery(all P&#x0026;#x003C;0.05), but there were no statistical differences in UCVA, chamber angle, central anterior chamber depth and anterior chamber volume at each time point after surgery(all P&#x0026;#x003E;0.05). The intraocular pressure at 1mo after surgery was lower than that before surgery(P&#x0026;#x003C;0.05), but the intraocular pressure at 3, 6mo and 1a after surgery and at the last follow-up was not statistically different from that before surgery(all P&#x0026;#x003E;0.05). There was no statistical significance in the corneal endothelial cell density at 1, 3, 6mo and 1a after surgery and at the last follow-up compared with that before surgery(all P&#x0026;#x003E;0.05). The vault at 1, 3, 6mo and 1a after surgery and at the last follow-up showed a decreasing trend, and the difference was statistically significant at each time point after surgery(all P&#x0026;#x003C;0.05).CONCLUSION: The short-term and long-term efficacy are better in moderate and high myopia patients with vault greater than 1 000 μm after ICL implantation, and there are no significant effects on the intraocular pressure and corneal endothelial cell. The postoperative anterior chamber structure is relatively stable and the vault tends to decrease over time. In most cases, close observation is sufficient and intraocular lens replacement is generally not required.

10.
Arq. bras. oftalmol ; 85(1): 68-76, Jan.-Feb. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1350084

ABSTRACT

ABSTRACT Purpose: To translate and validate the Contact Lens Dry Eyes Questionnaire (CLDEQ-8) to Portuguese language and to describe the impact of soft contact lenses on the ocular surface. Methods: We conducted a descriptive transversal study with the aim to: (1) translate and validate the CLDEQ-8 questionnaire to Portuguese language and (2) apply the CLDEQ-8 to a group of contact lens wearers along with a broad evaluation of the impact of soft contact lens on the ocular surface. The evaluation of the impact of soft contact lens was performed for a study population of 81 subjects, categorized in two groups: Group A: 61 contact lens wearers and Group B (control): 20 noncontact lens wearers. The study exclusion criteria were rigid contact lens wear, systemic or ocular diseases, the use of medications predisposing to ocular surface damage, and previous ocular surgeries. Results: For the CLDEQ-8 questionnaire translation and validation, Kappa agreement values were ³0.7 in all questions, implying a good agreement between the Portuguese and English language versions. Considering the ocular surface evaluation of the subjects, all parameters differed in Soft contact lens wearers when compared with the controls (p<0.05), except in those related to tear volume, such as the tear meniscus height and Schirmer test. Conclusions: This study provided a translated and validated Portuguese version of CLDEQ-8 questionnaire, which represents an important tool for the evolution of contact lens wearers. The broad evaluation of the ocular surface revealed an association between soft contact lens wearing and ocular surface disturbances.


RESUMO Objetivo: Traduzir e validar o questionário de olho seco e lentes de contato (CLDEQ-8) para o português e descrever o impacto das lentes de contato gelatinosas na superfície ocular. Métodos: Estudo transversal e descritivo com o objetivo de (1) traduzir e validar o CLDEQ-8 para o português e (2) aplicar o CLDEQ-8 em um grupo de usuários de lentes de contato, juntamente com uma ampla avaliação do impacto das lentes gelatinosas na superfície ocular. A avaliação do impacto das lentes gelatinosas foi realizada em uma amostra composta por 81 indivíduos, divididos em dois grupos: 61 usuários de lente de contato (Grupo A) e um grupo controle de 20 não usuários (Grupo B). Como critério de exclusão: usuário de lentes de contato rígidas, doenças sistêmicas ou oculares prévias, uso de medicamentos que podem causar danos a superfície ocular e cirurgias oculares prévias. Resultados: Para a tradução e validação do questionário CLDEQ-8, os valores de concordância Kappa foram iguais ou superiores a 0,7 em todas as perguntas, o que implica em uma boa concordância entre as versões em português e inglês. Considerando a avaliação da superfície ocular dos sujeitos, todos os parâmetros diferiram nos usuários de lente de contato em comparação com os controles (com p<0,05), exceto naqueles relacionados ao volume lacrimal, como altura do menisco lacrimal e teste de Schirmer. Conclusões: Este estudo forneceu uma versão traduzida para o português e validada do questionário CLDEQ-8, que representa uma importante ferramenta na avaliação de usuários de lente de contato. A avaliação da superfície ocular realizada demonstra a relação entre o uso de lentes de contato gelatinosas e os distúrbios da superfície ocular.

11.
International Eye Science ; (12): 260-264, 2022.
Article in Chinese | WPRIM | ID: wpr-913034

ABSTRACT

@#Myopia is a common ocular disorder. In recent years, the incidence of myopia presents an increasing trend year by year. Patients with high myopia are at an increased risk for severe visual impairment. The economic and societal impacts of complication associated with myopia are enormous. Therefore, it is essential and imminent for implementing effective myopia control strategies. The results of the current study suggest that uncontrolled axial elongation produced by periphral hyperopic defocus could be one of the possible mechanisms for myopia development, multiple strategies especially optical defocus technology based on this are increasingly becoming part of the mainstream clinical practice in myopia management. This article reviews the principle of optical defocus on myopia control, experimental research on defocus myopia animals, and the latest clinical applications of different optical defocus technologies on myopia control, summarizes the clinical research results of myopia control using progressive addition spectacle lenses, peripheral defocus spectacle lenses, defocus incorporated multiple segments spectacle lenses, orthokeratology contact lenses and multifocal soft contact lenses. It is proposed to provide a new option for the treatment plan to delay the progression of myopia.

12.
International Eye Science ; (12): 109-111, 2022.
Article in Chinese | WPRIM | ID: wpr-906742

ABSTRACT

@#AIM:To investigate the application of multi-mode teaching steered by “HOPE” in the clinical teaching of contact lens.<p>METHODS: Prospective study. Two classes(totally 80 students)of 2018 grade major in optometry, Nanjing Medical University, were randomly selected as experimental group(40 students, 18 males, 22 females)using multi-mode teaching(including problem-based learning, case-based learning and flipped classroom),and control group(40 students, 19 males, 21 females)using traditional teaching mode. At the end of the course, the teaching effects were evaluated by usual performance, network examination, theory test, operation test and questionnaire.<p>RESULTS: The assessment result at ordinary times: the points of experiment group(16.46±2.19)points was higher than the control group(13.81±2.95)points(<i>t</i>=6.36, <i>P<</i>0.01); Network examination result: the points of experiment group(9.37±1.57)points was higher than the control group(7.21±1.46)points(<i>t</i>=4.39, <i>P=</i>0.01); Theory of the assessment result: the points of experiment group(40.41±3.48)points was higher than the control group(36.29±3.34)points(<i>t</i>=9.25, <i>P</i><0.01); The assessment result of operation: the points of experiment group(18.22±2.69)was higher than the control group(16.28±2.52)(<i>t</i>=3.25, <i>P=</i>0.02); Total grade: the points of experiment group(84.46±5.26)was higher than the control group(73.69±6.35)(<i>t</i>=11.26,<i>P<</i>0.01). Contact lens teaching effect feedback questionnaire results showed that: students based on the concept of “HOPE” teaching mode were more satisfied than control group, and they think it had more advantages than traditional teaching group in learning initiative and improving teaching efficiency, cultivating clinical thinking ability, improving the communication power of expression(all <i>P<</i>0.05).<p>CONCLUSION: Multi-mode teaching(PBL, CBL and flipped classroom)steered by “HOPE” in the clinical teaching of contact lens can stimulate students'interest in learning, improve the quality of teaching and achieve better teaching effect.

13.
International Eye Science ; (12): 434-437, 2022.
Article in Chinese | WPRIM | ID: wpr-920424

ABSTRACT

@#High intraocular pressure is the most concerned complication of the implantation surgery of V4c implantable contact lens(ICL). According to the appearance time of intraocular pressure elevation, it can be divided into three periods: the early period(1wk after surgery), the middle period(1-4wk after surgery)and the late period(1-3mo after surgery). During the early period, the intraocular pressure increase is mainly caused by the residue of the intraoperative viscoelastic. In the middle period, the application of the hormone drugs results the elevation of the intraocular pressure. Furthermore, during the late period, persistent increasing of the intraocular pressure may cause the secondary glaucoma. Identifying the mechanism of different periods of intraocular pressure rise correctly and thus formulating a reasonable treatment plan, is of great significance for the prevention of glaucoma and other long-term vision threatening complications. Therefore, this article reviews the appearance time and mechanism of the intraocular pressure rise after surgery.

14.
International Eye Science ; (12): 1647-1651, 2022.
Article in Chinese | WPRIM | ID: wpr-942834

ABSTRACT

Conventional eye treatment formulation such as eye drops has shortcomings including low drug utilization and poor patient compliance. The contact lens(CL), well-known as visual correction lens, is considered to be a more promising ophthalmic drug delivery vehicle owing to its good biocompatibility, long-term wearing comfort, prolonged drug residence time and improved bioavailability. In order to improve the drug loading efficiency and prolong the release time, researchers have developed a variety of strategies to modify traditional CL, including the introduction of vitamin E molecular barrier, application of molecular imprinting technology of CL, increasing interactions between the drug and polymer matrix by introducing special genes, and incorporation of nanocarriers or drug-loaded polymer films. In this paper, the preparation methods and pros and cons of drug-loaded CL are reviewed. At last, the existing problems and future developments of CL as ophthalmic drug delivery carrier are briefly discussed.

15.
Article in English | LILACS-Express | LILACS | ID: biblio-1385855

ABSTRACT

ABSTRACT: Currently, the aesthetic requirements of patients are increasing and they have begun to request more conservative treatments. One alternative to achieve harmonious results is through the indication of ultra-thin veneers. This is considered a conservative technique but the evidence basis for it seems to be limited. The following review attempts to summarize the relevant literature to establish guidelines for clinicians based on scientific evidence regarding the use of ultra-thin veneers. Ultra-thin veneers seem to be a reliable alternative to achieve aesthetic and harmonious results; however, many factors must be considered to ensure correct diagnosis and treatment plan. In addition, the literature is scarce in relation to a consensus on tooth preparation and long-term studies evaluating the success of this type of treatment over time do not exist.


RESUMEN: Actualmente, los requisitos estéticos de los pacientes han aumentando y solicitan tratamientos más conservadores. Una alternativa para lograr resultados armónicos es mediante la indicación de carillas o laminados ultrafinos. Esta se considera una técnica conservadora, pero la base teórica parece ser limitada. La siguiente revisión intenta resumir la literatura relevante para establecer pautas para clínicas basadas en evidencia científica sobre el uso de carillas ultrafinas. Las carillas ultrafinas parecen ser una alternativa confiable para lograr resultados estéticos y armónicos; sin embargo, se deben considerar muchos factores para asegurar un diagnóstico y plan de tratamiento correcto. Además, la literatura es escasa en relación a un consenso sobre la preparación dental y no existen estudios a largo plazo que evalúen el éxito de este tipo de tratamiento a lo largo del tiempo.

16.
Arq. bras. oftalmol ; 84(5): 462-466, Sept.-Oct. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1339212

ABSTRACT

ABSTRACT Purpose: Microcornea is a rare condition that frequently resulets in serious cosmetic concerns due to the resultant asymmetrical appearance of the eye, and its cosmetic rehabilitation is possible with the use of colored contact lenses. This paper aims to present our experiences with the use of cosmetic Etafilcon A contact lenses for microcornea. Methods: Eight patients with unilateral microcornea without any systemic involvement were included in this study, and they underwent routine ophthalmological examination, corneal topography, and optical biometry. We applied the cosmetic Etafilcon A contact lens (1-DAY ACUVUE® DEFINE® with Lacreon®) of the same edge color to the patients. The levels of satisfaction in terms of cosmesis and comfort were evaluated with the use of visual analog scales (VAS). Results: In the patients, the corneal diameter asymmetry was acceptably adjusted, and each of the patients reported extreme satisfaction. The mean VAS score was 8.9 ± 1.0 (range: 7-10) for the cosmetic satisfaction rate and 8.4 ± 1.0 (range: 7-10) for the comfort rate. The patients obtained the best-corrected visual acuity without or with additional eye-glasses. None of the patients complained about vision issues under photopic and scotopic conditions. Conclusion: 1-DAY ACUVUE® DEFINE® with Lacreon® lens has promising satisfactory cosmetic outcomes along with visual enhancement in cases of microcornea. This is the first study to report the use of this lens for the cosmetic rehabilitation of patients with microcornea.


RESUMO Objetivo: A microcórnea é uma afecção rara, que frequentemente causa graves queixas estéticas devido a uma aparência assimétrica, mas passível de reabilitação estética através de lentes de contato coloridas. O objetivo deste estudo é apresentar nossas experiências no uso de lentes de contato cosméticas Etafilcon A em casos de microcórnea. Métodos: Oito pacientes com microcórnea unilateral, sem acometimento sistêmico, foram incluídos e submetidos a exame oftalmológico de rotina, topografia corneana e biometria óptica. Aplicamos nos pacientes uma lente de contato cosmética Etafilcon A (1-Day Acuvue® Define® com Lacreon®) da mesma cor da borda da córnea dos pacientes. Os níveis de satisfação em termos de estética e conforto foram avaliados por meio de escalas visuais analógicas (EVA). Resultados: A assimetria do diâmetro da córnea foi corrigida em um grau aceitável e todos os pacientes ficaram muito satisfeitos. A pontuação média da EVA foi de 8,9 ± 1,0 (variação: 7-10) para o grau de satisfação estética e 8,4 ± 1,0 (intervalo: 7-10) para o grau de conforto. Os pacientes obtiveram a melhor acuidade visual corrigida com ou sem óculos adicionais. Não houve queixas visuais em condições fotópicas ou escotópicas. Conclusão: A lente 1-Day Acuvue® Define® com Lacreon® é promissora em termos de resultados estéticos satisfatórios, bem como de melhoria da visão em casos de microcórnea. Este é o primeiro estudo a relatar o uso dessa lente na reabilitação cosmética de pacientes com microcórnea.

17.
International Eye Science ; (12): 1257-1260, 2021.
Article in Chinese | WPRIM | ID: wpr-877400

ABSTRACT

@#AIM: To investigate the clinical effect of transepithelial rapid cross-linking combined with wearing rigid gas permeable contact lens(RGPCL)in keratoconus patients.<p>METHODS: This was a retrospective study of patients with progressive keratoconus diagnosed in the Second Affiliated Hospital of Fujian University of Traditional Chinese Medicine in October 2014, and underwent transepithelial rapid keratoplasty. After surgery 16 patients(25 eyes)used RGPCL. Average age was 25.31±5.92 years old, maximum preoperative corneal curvature was 58.96±6.76D, thinnest corneal thickness was 439.52±53.24μm. Rapid cross-linking was performed using riboflavin and 45mW/cm<sup>2</sup> ultraviolet light(UV)irradiation with a total energy of 7.2J/cm<sup>2</sup>. RGPCL was used after surgery. Follow up of 3-6a, average follow-up time was 52.44±11.39mo. The best corrected visual acuity \〖(BCVA), in RGPCL\〗, corneal curvature of flat meridian(K<sub>1</sub>), corneal curvature of steep meridian(K<sub>2</sub>), maximum corneal curvature(Kmax), corneal refractive power(MPP), Baiocchi Calossi Versaci index of anterior and posterior surface(BCVf and BCVb)asymmetry index of anterior surface curvature(SIf), asymmetry index of posterior surface curvature(SIb), the highest point of anterior cone cornea(KVf), the highest point of posterior cone cornea(KVb), the change of corneal thickness(ThkMin), lens opacity, and corneal endothelial cell count were observed.<p>RESULTS: All patients had a successful operation, and no intraoperative complications. On the first day after surgery, all cases felt slight tingling and slight photophobia tears. After 1d of operation, the corneal epithelium was removed in two eyes. While 3d after re-wearing the bandage, the epithelium healed. None of lens in the patients was opacified during follow-up, and there was no significant difference in corneal endothelial cell count compared with preoperative(<i>P</i>>0.05). The BCVA(wearing RGPCL)after operation is obviously improved compared with preoperative. All postoperative Kmax, SIf, KVf, BCVf, BCVb were lower than preoperative(<i>P</i><0.05). <p>CONCLUSION: Transepithelial rapid corneal cross-linking combined with RGPCL is safe and effective in controlling the progress of keratoconus. And the long-term effect is stable.

18.
International Eye Science ; (12): 1221-1226, 2021.
Article in Chinese | WPRIM | ID: wpr-877389

ABSTRACT

@#AIM: To evaluate the efficacy evaluation of the combined application of bandage contact lens after pterygium excision surgery by Meta-analysis.<p>METHODS: Randomized controlled clinical studies on combined application of corneal bandage contact lens after pterygium excision were retrieved from PubMed, Cochrane Library, Wanfang, VIP, CNKI and other databases from May 2014 to May 2020. Data were extracted and Meta-analysis was performed.<p>RESULTS:Totally 11 randomized controlled clinical studies were included, including 10 in Chinese and 1 in English, with 864 patients. Meta-analysis results showed that 1d postoperative \〖<i>MD</i>= -1.57, 95%<i>CI</i>=(-1.72, -1.41), <i>P</i><0.00001\〗, 2d postoperative \〖<i>MD</i>= -1.35, 95%<i>CI</i>=(-1.59, -1.11), <i>P</i><0.00001\〗, 7d postoperative \〖<i>MD</i>= -0.64, 95%<i>CI</i>=(-0.78, -0.50), <i>P</i><0.00001\〗 combined application of corneal bandage contact lens can better reduce the degree of ocular pain in patients; And 1d postoperative \〖<i>MD</i>= -1.23, 95%<i>CI</i>=(-1.51, -0.95), <i>P</i><0.00001\〗, 7d postoperative\〖<i>MD</i>= -0.44, 95%<i>CI</i>=(-0.50, -0.39), <i>P</i><0.00001\〗 combined application of corneal bandage contact lens can better promote the condition of corneal epithelium. <p>CONCLUSION:The bandage contact lens could markedly release pain response after pterygium excision surgery, promote corneal epithelium recovery, which is beneficial to reduce the symptoms of clinical discomfort.

19.
International Eye Science ; (12): 1072-1076, 2021.
Article in Chinese | WPRIM | ID: wpr-876758

ABSTRACT

@#AIM: To observe the changes of the vault height and the correlation analysis of visual quality under different pupil diameters after ICL surgery.<p>METHODS: Retrospective case study. Selected 43 patients(86 eyes)who implanted V4c ICL surgery successfully at Shanghai Aier Eye Hospital and followed up regularly to meet the measurement requirements from January 2018 to January 2019, Routine parameters and iTrace were checked before and 1wk, 1mo, and 3mo after surgery. Visante-OCT was used to measure the vault height under the pupils of 3mm and 5mm. <p>RESULTS: The vault height under the 3mm pupil at 1wk, 1mo and 3mo after surgery were(586.06±24.49, 560.16±21.31, 508.19±21.17)μm, the values under the 5mm pupil were(698.13±20.98, 667.69±20.16, 613.28±19.79)μm(<i>F</i><sub>Time</sub>=40.160,<i>P</i><sub>Time</sub><0.001; <i>F</i><sub>Groups</sub>=56.835,<i>P</i><sub>Groups</sub><0.001). The wave of vaule under the different pupils was(112.06±8.91, 107.53±6.94,101.01±10.64)μm(<i>F</i>=16.875, <i>P</i>>0.05). The total high-order aberration(HOA)and RMS of the whole eye after ICL were significantly reduced(<i>F</i>=29.847, 85.019; <i>P</i><0.001). The MTF and SR value were significantly higher than before surgery(<i>F</i>=47.653, 33.264; <i>P</i><0.001), and there was no statistical difference after ICL. At 3mo after surgery, the RMS and MTF values at 3mm and 5mm pupils were compared. The RMS value of the total HOA under the pupil of 5mm is significantly higher than that at 3mm, and the increase of spherical and trefoil aberration is significant(<i>t</i>=21.812, 17.136; <i>P</i><0.001). No significant difference in coma value(<i>t</i>=2.028, <i>P</i>>0.05). The MTF at 5mm pupils were significantly lower than those at 3mm at spatial frequencies of 5, 10, 15, 20, 25, 30c/d(<i>t</i>=15.138, 9.147, 7.018, 4.693, 3.814 and 3.075, all <i>P</i><0.05).<p>CONCLUSION: The impact of pupil movement on vault height fluctuation is about 110μm. It is recommended that the minimum vault height should be above 300μm. It can significantly reduce the root mean square value of total high-order aberration and aberration of the whole eye, and significantly increase the MTF and SR values after ICL surgery. The pupil size has a significant effect on visual quality after ICL. The spherical aberration and trefoil aberration increase under the condition of large pupil, and the MTF value generally decreases.

20.
International Eye Science ; (12): 919-922, 2021.
Article in Chinese | WPRIM | ID: wpr-876027

ABSTRACT

@#AIM: To analyze the influence of bandage contact lens on corneal refractive status and postoperative complications in patients with pterygium. <p>METHODS: Totally 116 patients with pterygium treated in the hospital between January 2018 and December 2019 were recruited in the study. They were divided into control group and observation group by random number table method, 58 cases in each group. The control group received extended pterygium resection and autologous corneal limbal stem cell transplantation. On this basis, the observation group was treated with bandage contact lens. The best corrected visual acuity(BCVA), surface asymmetry index(SAI)of corneal topography, surface regularity index(SRI), corneal refractive power and postoperative complications in the two groups were compared. <p>RESULTS: Compared with preoperation, the BCVA of the two groups was significantly higher 1mo and 3mo after operation(<i>P</i><0.05), without statistically significant difference between the groups(<i>P</i>>0.05). Corneal horizontal and vertical curvature of the two groups were significantly higher, while corneal astigmatism was significantly lower at 1mo and 3mo after surgery. Meanwhile, the observation group had significantly lower corneal astigmatism than the control group(<i>P</i><0.05). SAI and SRI of the two groups significantly decreased, which were significantly lower in the observation group than in the control group(<i>P</i><0.05). No complications such as infection, poor healing of grafts and subconjunctival cysts were observed. The incidence of eye irritation was significantly lower in the observation group than in the control group, and lower at 2wk than at 1wk before operation(<i>P</i><0.05).<p>CONCLUSION: Extended pterygium resection combined with autologous corneal limbal stem cell transplantation and bandage contact lens is more conductive to the improvement of corneal refraction in patients with pterygium, which also can reduce the incidence of eye irritation.

SELECTION OF CITATIONS
SEARCH DETAIL